AFC300 Series 3 phase High Power AC Power Source
- Features:
The AFC300 Series 3 Phase High Power AC Power Source is integrated with
the IGBT/SPWM technology, simple operation but provides reliable high
quality pure sine wave with output power up to 2,000kVA, output
frequency of 50/60Hz fixed, 45-65Hz adjustable(opt 45-400Hz). The AFC300
Series is the ideal power solution for industrial high power motors,
air conditioning systems and electrical charging stations.
Dongguan Sophpower Electronics Co., Ltd
lSingle phase output from 500VA-100kVA,three phase output from 10kVA-2000kVA.
l4 LED display measurements of voltage, current, frequency and power/PF.
lAutomatic high and low range voltage:0-150V/150.1-300V automatic switch, or 1-300V high range locked.
lComprehensive protection includes over voltage, over current, over load, input under voltage and over temperature with corresponding error codes.
lStrong shock resistance, able to start the loads of 1/3 rated power of the AC power supply directly.
lThree phase independent loading, and able to start each phase separately.
lOutput voltage and frequency adjustable at output state.
lSimple operate with lock key, shortcut key and knob.
lStandard RS232 interface, optional RS485 and GPIB interface.
lWith power-off memory function, remember the last output parameters automatically.
Specification
3 phase input 3 phase output (10kVA – 75kVA)
Model | AFC-310 | AFC-315 | AFC-320 | AFC-330 | AFC-345 | AFC-360 | AFC-375 | ||
Input Specifications | |||||||||
Phase | 3ϕ4W + PE | ||||||||
Voltage | 380V ± 10%(Please contact us for other input voltage) | ||||||||
Frequency | 50/60Hz ± 5% | ||||||||
Out Specifications | |||||||||
Capacity | 10kVA | 15kVA | 20kVA | 30kVA | 45kVA | 60kVA | 75kVA | ||
Phase | 3ϕ4W + PE | ||||||||
Max Current | 0-150V Range | 27.6A | 42A | 54A | 84A | 126A | 168 A | 210A | |
0-300V Range | 13.8A | 21A | 27A | 42A | 63A | 84A | 105A | ||
Voltage | Line to Neutral | 0-150V/ 0-300V Variable(Opt. 0-600V) | |||||||
Line to Line | 0-260V/ 0-520V Variable(Opt. 0-1040V) | ||||||||
Transient Response | 30ms | ||||||||
Frequency | 50Hz, 60Hz, 45~65Hz Variable(Opt. 45~400Hz) | ||||||||
Phase Difference | 120 ° ± 2 ° | ||||||||
Total Harmonic Distortion(THD) | ≤ 1% (Resistive Load, At full load 2% ) | ||||||||
Voltage Regulation | ≤ 1% | ||||||||
Load Regulation | ≤ 1% (Resistive Load) | ||||||||
Frequency Regulation | ≤ 0.01% | ||||||||
Efficiency | ≥ 85% ( At full load ) | ||||||||
Protection | Over Current, Short Circuit, Over Temperature , Over Load ,Phase Deficient, Low-voltage Protection, Alarms | ||||||||
Overload Capacity | 100%<Output ≤ 110% 27min Cut-off output; 110%<Output ≤ 130% 10s Cut-off output; 130%<Output ≤ 150% 5s Cut-off output; 150%<Output Cut-off output immediately. | ||||||||
Measurement | Current(RMS) | Resolution: 1mA/10mA or 10mA/100mA Accuracy: 0.3% F.S. ± 3 Counts ± 0.1%/100Hz | |||||||
Voltage(RMS) | Resolution: 0.1V Accuracy: 0.3% F.S. ± 2 Counts ± 0.1%/100Hz | ||||||||
Frequency | Resolution: 0.01Hz/0.1Hz Accuracy: 0.3% F.S. ± 2 Counts ± 0.05%/100Hz | ||||||||
Working Environment | |||||||||
Operating Temperature | 0 ° - 40 ° C/ 32 ° - 104 ° F | ||||||||
Relative Humidity | 10-90% ( Non-condensing ) | ||||||||
Functions | |||||||||
4 Digits LED Display | Voltage, Current, Frequency | ||||||||
Interface | Standard: RS232 (Opt. RS485, GPIB) | ||||||||
Memory Function | With power-off memory function, remember the last output parameters automatically. | ||||||||
Sync Output Signal | Support | ||||||||
Mechanical Specifications | |||||||||
Dimensions(W x H x D)(mm) | 565 x 890 x 650 | 690 x 1510 x 590 | 750 x 1605 x 900 | ||||||
Weights(Kg) | 140 | 160 | 200 | 360 | 450 | 540 | 600 |
3 phase input 3 phase output (90kVA – 1000kVA)
Model | AFC-390 | AFC-3120 | AFC-3150 | AFC-3240 | AFC-3500 | AFC-3750 | AFC-31000 | |
Input Specifications | ||||||||
Phase | 3ϕ4W + PE | |||||||
Voltage | 380V ± 10%(Please contact us for other input voltage) | |||||||
Frequency | 50/60Hz ± 5% | |||||||
Out Specifications | ||||||||
Capacity | 90kVA | 120kVA | 150kVA | 240kVA | 500kVA | 750kVA | 1000kVA | |
Phase | 3ϕ4W + PE | |||||||
Max Current | 0-150V Range | 250A | 333A | 416A | 666A | 1388A | 2082A | 2776A |
0-300V Range | 125A | 166A | 208A | 333A | 694A | 1041A | 1388A | |
Voltage | Line to Neutral | 0-150V/ 0-300V Variable(Opt. 0-600V) | ||||||
Line to Line | 0-260V/ 0-520V Variable(Opt. 0-1040V) | |||||||
Transient Response | 30ms | |||||||
Frequency | 50Hz, 60Hz, 45~65Hz Variable(Opt. 45~400Hz) | |||||||
Phase Difference | 120 ° ± 2 ° | |||||||
Total Harmonic Distortion(THD) | ≤ 1% (Resistive Load, At full load 2% ) | |||||||
Voltage Regulation | ≤ 1% | |||||||
Load Regulation | ≤ 1% (Resistive Load) | |||||||
Frequency Regulation | ≤ 0.01% | |||||||
Efficiency | ≥ 85% ( At full load ) | |||||||
Protection | Over Current, Short Circuit, Over Temperature , Over Load ,Phase Deficient, Low-voltage Protection, Alarms | |||||||
Overload Capacity | 100%<Output ≤ 110% 27min Cut-off output; 110%<Output ≤ 130% 10s Cut-off output; 130%<Output ≤ 150% 5s Cut-off output; 150%<Output Cut-off output immediately. | |||||||
Measurement | Current(RMS) | Resolution: 1mA/10mA or 10mA/100mA Accuracy: 0.3% F.S. ± 3 Counts ± 0.1%/100Hz | ||||||
Voltage(RMS) | Resolution: 0.1V Accuracy: 0.3% F.S. ± 2 Counts ± 0.1%/100Hz | |||||||
Frequency | Resolution: 0.01Hz/0.1Hz Accuracy: 0.3% F.S. ± 2 Counts ± 0.05%/100Hz | |||||||
Working Environment | ||||||||
Operating Temperature | 0 ° - 40 ° C/ 32 ° - 104 ° F | |||||||
Relative Humidity | 10-90% ( Non-condensing ) | |||||||
Functions | ||||||||
4 Digits LED Display | Voltage, Current, Frequency | |||||||
Interface | RS232 (Opt. RS485 , GPIB) | |||||||
Memory Function | With power-off memory function, remember the last output parameters automatically. | |||||||
Sync Output Signal | Support | |||||||
Mechanical Specifications | ||||||||
Dimensions(W x H x D)(mm) | 1130 x 1600 x 690 | 1120 x 1740 x 1235 | 3300 x 1740 x 1235 | |||||